Original Article
A Comparative Study on Repair of Canine Femoral Fractures Using Titanium and Stainless Steel Intramedullary Interlocking Nail
Year: 2024 | Month: August | Volume 14 | Issue 4
1.Abhishek, B., Reddy, J.M.K., Chandrasekhar, E.L., Rao, R.K.J. and Rajendranath, N. 2022. Clinical study on repair of tibial fractures using intramedullary interlocking nailing in dogs. The Pharma Innov. J., 11(11S): 1755-1761.
View at Google Scholar2.African, M., Alkan, F., Altan, S., Parlak, K. and Yavru, N. 2017. Clinical Experience of Interlocking Nail Stabilization of Long Bone Fractures in Dogs–A Retrospective Study of 26 Cases. Israel J. Vet. Med., 72(2): 45-50.
View at Google Scholar3.Bernarde, A., Diop A, Maurel N. and Viguier E. 2001. An in vitro biomechanical study of bone plate and interlocking nail in a canine diaphyseal femoral fracture model. Vet. Surg., 30(5): 397-408.
View at Google Scholar4.Bhat, A.K., Rao, S.K. and Bhaskaranand, K. 2006. Mechanical failure in intramedullary interlocking nails. J. Orthop. Surg., 14(2): 138 – 141.
View at Google Scholar5.Boyer, B., Welsch, G. and Collings, E.W. 2007. Materials Properties Handbook: Titanium Alloys, ASM International, Ohio., pp. 94–102.
View at Google Scholar6.Budsberg, S.C. 2005. Complications of fracture treatment. In Johnson AL, Houlton JEF, Vannini R, editors: AO principle of fracture management in the dog and cat, Davos, Switzerland, AO Publishing, pp. 416.
View at Google Scholar7.Déjardin, L.M., Guiot, L.P. and Von Pfeil, D.J. 2012. Interlocking nails and minimally invasive osteosynthesis. Vet. Clin.: Small Anim. Pract., 42(5): 935- 962.
View at Google Scholar8.Déjardin, L.M., Perry, K.L., Von Pfeil, D.J. and Guiot, L.P. 2020. Interlocking nails and minimally invasive osteosynthesis. Vet. Clin.: Small Anim. Pract., 50(1): 67-100.
View at Google Scholar9.Diaz, M.C., Durall, I., Franch, J. and Puchol, J.L. 2003. Radiographic findings related to interlocking nailing: windshield-wiper effect, and locking screw failure. Vet. Comp. Orthop. Traumatol., 16(4): 217-222.
View at Google Scholar10.Disegi, J.A. and Eschbach, L. 2000. Stainless steel in bone surgery. Injury, 31(Suppl4): 2-6.
View at Google Scholar11.Dueland, R.T., Johnson, K.A., Roe, S.C., Engen, M.H. and Lesser, A.S. 1999. Interlocking nail treatment of diaphyseal long-bone fractures in dogs. J. Am. Vet. Medical Assoc., 214(1): 59-66.
View at Google Scholar12.Duhautois, B. 2003. Use of veterinary interlocking nails for diaphyseal fractures in dogs and cats: 121 cases. Vet. Surg., 32(1): 8-20.
View at Google Scholar13.Durall, I., Diaz-Bertrana, M.C., Puchol, J.L. and Franch, J. 2003. Radiographic findings related to interlocking nailing: windshield-wiper effect, and locking screw failure. Vet. Comp. Orthop. Traumatol., 16(04): 217-22.
View at Google Scholar14.Endo, K., Nakamura, K., Maeda, H. and Matsushita, T. 1998. Interlocking intramedullary nail method for the treatment of femoral and tibial fractures in cats and small dogs. J. Vet. Medical Sci., 60(1): 119-122.
View at Google Scholar15.Ferrell, M. 2016. Orthopaedic implants. In BSAVA Manual of Canine and Feline Fracture Repair and Management . British Small Animal Veterinary Association, Gloucester . 2 nd edn., pp: 72-87,
View at Google Scholar16.Fossum, T.W. 2013. Small animal surgery textbook. 4th Edn Elsevier Health Sciences pp. 1082- 1083, 1086-1093, and 1102- 1105.
View at Google Scholar17.Horstman, C.L., Beale, B.S., Conzemius, M.G. and Evans, R. 2004. Biological osteosynthesis versus traditional anatomic reconstruction of 20 long-bone fractures using an interlocking nail: 1994–2001. Vet. Surg., 33(3): 232-237.
View at Google Scholar18.Reddy J.M.K. and Kumar, D.D. 2021a. Clinical Efficacy on the Use of Titanium Intramedullary Interlocking Nailing (Ti-IILN) for Repair of Communited Diaphyseal Femur Fractures in Dogs. J. Anim. Res., 11(05): 807- 817.
View at Google Scholar19.Reddy J.M.K., Kumar, D.D., Chandra, S.E.L., Srikanth, K., Kumar, V.M. and Dhoolappa, M. 2021a. Clinical study on the use of Titanium Dynamic Compression Plate (Ti-DCP) for repair of femur fractures in dogs. The Pharma Innov. J., 9(12): 08-18.
View at Google Scholar20.Reddy J.M.K., Kumar, D.D., Chandrasekhar, E.L., Kulkarni, S., Kumar, V.M. and Dhoolappa, M. 2021b. Repair of femoral fractures using titanium implants of intramedullary inter locking nail, dynamic compression plate and locking compression plate in dogs. Doctoral dissertation submitted to Karnataka veterinary animal and fisheries sciences university, Bidar.
View at Google Scholar21.Reddy J.M.K. and Kumar, D.D. 2021b. Evaluation of titanium locking compression plates for surgical repair of diaphyseal femoral fractures in dogs. Indian J. Vet. Surg., 42(1): 16-19
View at Google Scholar22.Reddy, J.M.K. 2020. Clinical study on the use of supracondylar femur plate (plate/hockey stick plate) for repair of supracondylar femur fractures in cats. The Pharma Innov. J., 9(12S): 19-25.
View at Google Scholar23.Kaur, M. and Singh, K. 2019. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications. Materials Sci. Eng.: C, 102: 844-862.
View at Google Scholar24.Mahar, A.T., Lee, S.S., Lalonde, F.D., Impelluso, T. and Newton, P.O. 2004. Biomechanical comparison of stainless steel and titanium nails for fixation of simulated femoral fractures. J. Pediatric Orthop., 24: 638–641.
View at Google Scholar25.Patel, B.M., Kelawala, N.H., Parikh, P.V., Patil, D.B., Gupta, P. and Tank, P.H. 2007. Interlocking nails for repair of canine tibial shaft fractures under image intensifier. Indian J. Vet. Surg., 28(2): 123-4.
View at Google Scholar26.Patwa, R., Bishnoi, P., Palecha, S., Bishnoi, A.K. and Sharma, P. 2022. Clinical and radiographic assessment of the efficacy of demineralized bone matrix (DBM) in healing of long bone fractures stabilized by interlocking nail in dogs. Indian J. Vet. Surg., 43(1): 14-17.
View at Google Scholar27.Piermattei, D.L. and Flo, G.L. 1997. Fractures: classification, diagnosis and treatment and treatment. In: Brinker, Piermattei and Flo’s Handbook of Small Animal Orthopedics and Fracture Repair. 3rd edn. Saunders, Philadelphia, pp. 117-130.
View at Google Scholar28.Piermattei, D.L. and Johnson, K.A. 2014. The hind limb in an atlas of surgical approaches to the bones and joints of the dog and cat. 5th Ed. Saunders WB, Philadelphia. pp. 369.
View at Google Scholar29.Pravalika, E., Reddy, K.J.M., Latha, C., Rao, T.M. and Purshotham, G. 2022. A Clinical Study on the Use of Supracondylar Plate in the Treatment of Distal Femoral Fractures in Dogs. Indian J. Anim. Res., 56(5): 47-49.
View at Google Scholar30.Raghunath, M. and Singh, S.S. 2008. Intramedullary Interlocking Nailing for management of long bone diaphyseal fractures in dogs: a study of 17 clinical cases. Indian J. Vet. Surg., 29(2): 106-109.
View at Google Scholar31.Raghunath, M., Bishnoi, A.K., Singh, S.S., Singh, M., Sharma, A. and Atri, K. 2012. Management of segmental fractures of tibia and femur by static intramedullary interlocking nailing in Twelve Dogs. Int. J. Appl. Res. Vet. Med., 10(3): 45-50.
View at Google Scholar32.Basinger, R.R. and Suber, J.T. 2004. Two techniques for supplementing interlocking nail repair of fractures of the humerus, femur, and tibia: results in 12 dogs and cats. Vet. Surg., 33(6): 673-680.
View at Google Scholar33.Scotti, A., Klein, A., Pink, A., Hidalgo, M.P. and Fayolle. 2007. Retrograde placement of a novel 3.5 mm titanium interlocking nail for supracondylar and diaphyseal femoral fracture in cats. Vet. Comp. Orthop. Traumatol., 20: 211-218.
View at Google Scholar34.Singh, M., Yadav, R.K., Raghunath, M. and Singh, S.S. 2007. Repair of bilateral femur fracture with static intramedullary nailing in three dogs: a clinical report. Indian J. Vet. Surg., 28: 48-49.
View at Google Scholar35.Reddy, S.P., Reddy, J.M.K., Rao, R.K.J., Rao, M.T. and Purshotham, G. 2021. Clinical study on the surgical management of tibial fractures using titanium elastic nails in dogs. The Pharma Innov. J., 10(7): 705-716.
View at Google Scholar36.Staiger, M.P., Pietak, A.M., Huadmai, J. and Dias, G. 2006. Magnesium and its alloys as orthopaedic biomaterials: a review. Biomaterials, 27: 1728–1734.
View at Google Scholar37.Suber, J.T., Basinger, R.R. and Keller, W.G. 2002. Two unreported modes of interlocking nail failure: breakout and screw bending. Vet. Comp. Orthop. Traumatol., 15(04): 228- 32.
View at Google Scholar38.Varshneya, V., Kumar, G., Kumar, D. and Pandey, R.P. 2012. C-arm guided closed interlocking nailing for tibial shaft fracture repair in dogs. Indian J. Vet. Surg., 33(1): 67.
View at Google Scholar39.Vasseur, P.B., Johnson, A.L., Buderberg, S.C., Linwin, J.B., Toombs, J.P., Whitebain, J.G. and Lentz, E.L. 1995. Randomized, controlled trials of the efficacy of carprofen, a non-steroidal anti-inflammatory drug in the treatment of osteoarthritis in dog. J. Am. Vet. Medical Assoc., 206: 807- 811.
View at Google Scholar40.Wang, K.1996. The use of titanium for medical applications in the USA. Materials Sci. Eng., 213: 34- 37.
View at Google Scholar41.Wheeler, J.L., Lewis, D.D., Cross, A.R., Stubbs, W.P. and Parker, R.B. 2004. Intramedullary interlocking nail fixation in dogs and cats: clinical applications. Compendium, 26(7).
View at Google Scholar



